Sale!

47-22861-01 Rheem Ruud Furnace Limit Switch

$18.00 $16.00

The 47-22861-01 is a manual reset furnace limit switch which means you would need to reset the limit by pushing down on the red botton on top if the limit switch trips. This limit switch is set to open the circuit at 350 degrees F. This Furnace Limit Roll Out Switch will be Shipped the Next Business Day. Order before 9 AM. Eastern Time for Same Day Shipping.

2 in stock

SKU: RheemRuud ManualResetRolloutLimitSwitch47-22861-01 Categories: , , Tags: ,

Description

Purchase the 47-22861-01 Rheem Ruud Furnace Limit Switch from Us and Save!

This Furnace Limit Roll Out Switch will be Shipped the Next Business Day. Order before 9 AM. Eastern Time for Same Day Shipping.

We Would Love to Help You Out and Have Your Business!

rheemlogo ruudlogo1  Rheem factory1bbbAplus

  • The 47-22861-01 Rheem Ruud Furnace Limit Switch is brand new and comes in a Genuine sealed Protech factory parts bag.
  • The 47-22861-01 Rheem Ruud Furnace Limit Switch is set to open and break the circuit at 350 degrees F.
  • The 47-22861-01 is a manual reset furnace limit switch which means you would need to reset the limit by pushing down on the red botton on top if the limit switch trips.
  • Below we have a list of furnace models where this rollout limit switch is used.
  • FYI: A furnace limit is a safety device that is used to cut the gas burners off if the furnace over-heats. If your furnace is going off on limit you might have a stopped up vent pipe, a stopped up heat exchanger or a leaking heat exchanger. If you have to reset your limit, rollout switch by pressing the button down on top, I would recommend that you have the furnace checked out by a professional to make sure the furnace is safe. A stopped up vent pipe or leaking heat exchanger can produce carbon monoxide and hurt/harm you or your family. Many times when the furnace goes off on limit the fan blower will continuously blow because the furnace control board senses that the furnace has over-heated and needs to cool down.  The only way to get the blower to cut off is to turn off the furnace with the power switch. You can test a limit with a volt meter to see if it is open or not.  On most limits you should get 24 volts from each of the two wires on the limit to a good ground.
  • Please send us your furnace model number and serial number if you would like for us to check and make sure this is the right rollout, limit switch for your furnace. Our email address is: Support@arnoldservice.com
  • We would Love to Help You Out and Have Your Business!

47-22861-01 Rheem Ruud Furnace Limit Switch

This Rheem, Ruud 47-22861-01 rollout limit switch is used on the following furnace models and replaces the following part numbers on the right:

Model: Part:
UGDG 47-22861-01
VGDG 47-22861-01
UGDG 47-22861-01
VGDG 47-22861-01
UGDG 47-22861-01
VGDG 47-22861-01
UGDJ 47-22861-01
UGLG 47-22861-01
UGLH 47-22861-01
UGLH 47-22861-01
UGLJ 47-22861-01
UGLK 47-22861-01
UGLL 47-22861-01
UGPH 47-22861-01
UGPJ 47-22861-01
UGPK 47-22861-01
UGPL 47-22861-01
UGSA 47-22861-01
UGTJ 47-22861-01
UGVG 47-22861-01
UGVH 47-22861-01
UGVJ 47-22861-01
RKKB 47-22861-01
RKMB 47-22861-01
RRKA 47-22861-01
RRMA 47-22861-01
80LJ 47-22861-01
80PJ 47-22861-01
RKNB 47-22861-01
90TJ 47-22861-01
RKKB 47-22861-01
RKKB 47-22861-01
RKKL-B 47-22861-01
RKKL-B 47-22861-01
RKKL-B 47-22861-01
RKKL-B 47-22861-01
RKNL-B 47-22861-01
RKNL-B 47-22861-01
RKNL-B 47-22861-01
RKNL-B 47-22861-01
RKNL-B 47-22861-01
RKNL-B 47-22861-01
RKNL-B 47-22861-01
RKNL-C 47-22861-01
RKNL-C 47-22861-01
RKNL-C 47-22861-01
RKNL-C 47-22861-01
RKNL-C 47-22861-01
RKNL-C 47-22861-01
RKNL-C 47-22861-01
SKKL-B 47-22861-01
SKNL-B 47-22861-01
SKNL-B 47-22861-01
SKNL-B 47-22861-01
SKNL-B 47-22861-01
RKMB 47-22861-01
RKNB 47-22861-01
RKMB 47-22861-01
SGPG 47-22861-01

Additional information

Weight1.0 lbs
Dimensions6 × 4 × 5 in

Reviews

There are no reviews yet.

Be the first to review “47-22861-01 Rheem Ruud Furnace Limit Switch”

Your email address will not be published. Required fields are marked *